Process Impurities · Cat. no. BP-QP-R014-96
RNase Inhibitor ELISA Kit, BP-QP-R014
Quantifies RNase Inhibitor by sandwich ELISA.
0.23–57 ng/mL
Standard curve range
0.23 ng/mL
Limit of quantitation
CV < 10%
Intra-batch, inter-batch < 15%

Product overview
RNase Inhibitor ELISA Kit, BP-QP-R014, is a 96 T/Kit double-antibody sandwich ELISA kit for quantifying RNase Inhibitor in research and manufacturing samples. The manual states a 0.23-57 ng/mL standard curve range, a 0.23 ng/mL quantitation limit, intra-batch CV below 10%, inter-batch CV below 15%, and recovery between 75% and 125%.
Features and applications
Features
- ELISA double-antibody sandwich assay format.
- Supplied as 96 T/Kit.
- This kit has been fully evaluated, with a standard curve range of 0.23-57 ng/mL and a quantitation limit of 0.23 ng/mL. The intra-batch CV is less than 10%, and inter-batch CV is less than 15%; the recovery rates are between 75% and 125%.
- For research use only and not intended for medical diagnosis, as stated in the manual.
Applications
- This kit is used for the quantification of RNase Inhibitor in samples. This kit is for research and manufacturing use only and is not intended for medical diagnosis.
- Designed for quantification of RNase Inhibitor in research and manufacturing samples.
Components
| Box | Component | Specification | Storage temperature |
|---|---|---|---|
| Box 1 | RNase Inhibitor standard (5700 ng/mL) | 40 μL | -20±5°C |
| Box 2 | RNase Inhibitor detection antibody | 12 mL | 2-8°C |
| Concentrated Wash Buffer (20×) | 30 mL | ||
| Sample Diluent | 30 mL | ||
| TMB Substrate | 12 mL | ||
| Stop Solution | 6 mL | ||
| Anti-RNase Inhibitor coated plate | 12 × 8-well strips | ||
| Sealing film | 2 sheets | ||
| Instruction Manual | 1 copy |
Shipping and storage
| Condition | Recommendation |
|---|---|
| Storage | Box 1 (RNase Inhibitor standard): -20±5°C. Box 2 (all other components): 2-8°C. The shelf life of an unopened product is 12 months. After opening, the product is valid for 1 month (within the expiration date). After use, return the kit promptly to its specified storage conditions. Reagents in Box 1 should minimize repeated freeze-thaw cycles; no more than 6 freeze-thaw cycles are recommended. |
| Shipping | Ship at 2-8°C with refrigerated cold packs. |
| Handling | For research use only. Review the MSDS before use. |
Downloads
Need this product lyophilized, in bulk, or in a custom format?
The feasibility assessment is free of charge. Send the assay brief and target format.