Skip to content
ISO 13485 & 9001 certified
LAMP · Cat. no. HW205-R02

AcuGenix™ Hot Start LAMP Dye Master Mix-V2

AcuGenix™ Hot Start LAMP Dye Master Mix-V2, HW205-R02, is supplied for molecular diagnostic research and manufacturing workflows.

Glycerol-free
For lyophilized reagent development
15 freeze-thaw cycles
Plus 14 days at 37 °C, stable
Room-temp setup
Prevents non-specific amplification
AcuGenix™ Hot Start LAMP Dye Master Mix-V2
AcuGenix™ Hot Start LAMP Dye Master Mix-V2AcuGenix™ Lyo-Ready Hot Start LAMP Dye Master Mix-V2

Product overview

Loop mediated isothermal amplification (LAMP) is a nucleic acid amplification technique. This kit uses dye based isothermal amplification and can be used for qualitative detection of DNA in samples such as viruses.

Available versions

Cat. no.Product nameFormulation
HW205-R02AcuGenix™ Hot Start LAMP Dye Master Mix-V2Liquid (with glycerol)
FHW1007-R02AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2Lyo-ready

Features and applications

Features
  • Suitable for DNA sample detection by LAMP using intercalating dyes, requiring fluorescence detection instruments.
  • Reactions can be assembled at room temperature, effectively preventing non-specific amplification and enhancing reaction efficiency.
Applications
  • This kit employs a dye-based isothermal amplification method.
  • This kit does not contain glycerol components, making it suitable for those with lyophilization conditions to develop lyophilized reagents.

Components

ComponentSpecification/Notes
Liquid (with glycerol), HW205-R02
AcuGenix™ Bst Hot Start DNA Polymerase-V2 (8 U/µL)N/A
2×LAMP Premix Buffer ⅡIncluded component; refer to the instruction manual
50×LAMP Fluorescent Dye ⅡIncluded component; refer to the instruction manual
Lyo-ready, FHW1007-R02
10×LAMP Premix (DG) (Bst2.0 HS)10×
5×LAMP Lyophilization Buffer5×
50×LAMP Fluorescent Dye Ⅱ50×

Performance data

1. Accelerated Stability Test

Stored at -20°C Accelerated at 37°C for 7 d Accelerated at 37°C for 14 d
Channel2ng/μl0.2ng/μl0.02ng/μlNTC
FAMFHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Accelerated Stability Test - FAM - 2ng/μl (Stored at -20°C Accelerated at 37°C for 7 d Accelerated at 37°C for…)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Accelerated Stability Test - FAM - 0.2ng/μl (Stored at -20°C Accelerated at 37°C for 7 d Accelerated at 37°C…)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Accelerated Stability Test - FAM - 0.02ng/μl (Stored at -20°C Accelerated at 37°C for 7 d Accelerated at 37°C…)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Accelerated Stability Test - FAM - NTC (Stored at -20°C Accelerated at 37°C for 7 d Accelerated at 37°C for 14…)

NTC Testing Standard:NTC amplification start time >30 min;

Conclusion 1: FHW1007-R02 remains stable after being accelerated at 37°C for 7 and 14 days.

2. Freeze-Thaw Stability Test

Stored at -20°C 5 freeze-thaw cycles 10 freeze-thaw cycles 15 freeze-thaw cycles
Channel2ng/μl0.2ng/μl0.02ng/μlNTC
FAMFHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Freeze-Thaw Stability Test - FAM - 2ng/μl (Stored at -20°C 5 freeze-thaw cycles 10 freeze-thaw cycles 15 freeze-thaw cycles)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Freeze-Thaw Stability Test - FAM - 0.2ng/μl (Stored at -20°C 5 freeze-thaw cycles 10 freeze-thaw cycles 15 freeze-thaw cycles)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Freeze-Thaw Stability Test - FAM - 0.02ng/μl (Stored at -20°C 5 freeze-thaw cycles 10 freeze-thaw cycles 15 freeze-thaw cycles)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Freeze-Thaw Stability Test - FAM - NTC (Stored at -20°C 5 freeze-thaw cycles 10 freeze-thaw cycles 15 freeze-thaw cycles)

NTC Testing Standard:NTC amplification start time >30 min;

Conclusion 1: FHW1007-R02 remained stable after 15 freeze-thaw cycles.

3. Immediate Post-Lyophilization Test

FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Immediate Post-Lyophilization Test

All lyophilized beads were spherical, with smooth surfaces and no cracking, shrinkage, or melting.

■ Liquid Control ■ Lyophilized Beads
Channel0.1 pg/μl0.01 pg/μl0.001 pg/μlNTC
FAMFHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Immediate Post-Lyophilization Test - FAM - 0.1 pg/μl (■ Liquid Control ■ Lyophilized Beads)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Immediate Post-Lyophilization Test - FAM - 0.01 pg/μl (■ Liquid Control ■ Lyophilized Beads)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Immediate Post-Lyophilization Test - FAM - 0.001 pg/μl (■ Liquid Control ■ Lyophilized Beads)FHW1007-R02 AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2: Immediate Post-Lyophilization Test - FAM - NTC (■ Liquid Control ■ Lyophilized Beads)

NTC Testing Standard:NTC amplification start time >30 min;

Conclusion 1: The FHW1007-R02 lyophilised balls look normal after freeze-drying and perform just as well as the liquid control.

Shipping and storage

ConditionRecommendation
Shipping Conditions-20±5°C
Storage Conditions-20±5°C
Shelf Life18M

Downloads

AcuGenix™ Hot Start LAMP Dye Master Mix-V2 (HW205-R02)

Instruction Manual (PDF)COA (PDF)MSDS 1 (PDF)MSDS 2 (PDF)MSDS 3 (PDF)

AcuGenix™ Lyo-ready Hot Start LAMP Dye Master Mix-V2 (FHW1007-R02)

Instruction Manual (PDF)COA (PDF)MSDS 1 (PDF)MSDS 2 (PDF)MSDS 3 (PDF)

Need this product lyophilized, in bulk, or in a custom format?

The feasibility assessment is free of charge. Send the assay brief and target format.

Talk to an expert

Not ready for a quote? Discuss feasibility, formats, host systems or validation with the specialist behind this page — no sales script.

Topic detected: your enquiry

Reply within one business day from an application scientist. For pricing, COA or samples, use Request a quote instead.

Application scientistAssay integration & formats

Tell us what you want to discuss

Four fields. We route it to the right person and reply the way you prefer.

🔒 Used only to reply to this request. No newsletters. Privacy Policy

Need pricing, a COA or samples? Request a quote →

Quick Contact

* Your data is securely protected for essential communications only. We won’t share your details or send spam emails, Privacy Policy *