Skip to content
Lab ToolsFREE
ISO 13485 & 9001 certified

Western Blot Protocol at a Glance: 7 Steps From Lysis to ECL

A western blot protocol in seven steps, from sample lysis and protein quantification to SDS-PAGE, transfer, blocking, antibody incubation and ECL detection.

western blot protocol cover
On this page
  1. Step 1: Sample Lysis
  2. Step 2: Protein Quantification
  3. Step 3: SDS-PAGE Electrophoresis
  4. Step 4: Membrane Transfer
  5. Step 5: Blocking
  6. Step 6: Antibody Incubation and Washing
  7. Step 7: Signal Detection
  8. FAQ
    1. How should I store a western blot membrane after transfer or detection?
    2. What controls should I include in a western blot?
    3. How long does a western blot take?
    4. Can I use an HRP-labeled primary antibody without a secondary antibody?
  9. References

Published by Zhuhai Biori Biotechnology Co., Ltd.

The Western blot protocol runs in seven steps: sample lysis → protein quantification → SDS-PAGE electrophoresis → membrane transfer → blocking → antibody incubation and washing → signal detection. Run end to end, these western blot steps typically take about 1–2 days, with overnight primary-antibody incubation accounting for most of the waiting time. Transfer and blocking often determine whether the final image is interpretable: incomplete transfer and high background cannot be corrected downstream.[1]

Western blot (protein blotting) separates proteins by SDS-PAGE, transfers them onto a PVDF or NC membrane, and detects one specific target with a primary antibody, an enzyme-labeled secondary antibody and its substrate. Because molecular-weight separation is combined with antibody recognition, the method is specific, sensitive, and both qualitative and semi-quantitative. It is widely used in basic research, biomarker work and recombinant protein QC.

Key takeaways: western blot tips

  • Add EDTA-free protease and phosphatase inhibitors fresh at lysis; they are mandatory for phosphorylation targets.
  • Quantify every lysate (BCA or Bradford) — equal loading is what makes band intensities comparable.
  • Pick the gel percentage and membrane pore size by molecular weight: keep the target mid-gel; use 0.22 µm membranes for proteins < 20 kDa and 0.45 µm membranes for proteins > 20 kDa.
  • Match the blocker to the target: skim milk for routine work, BSA or protein-free blockers for phosphorylation and avidin–biotin systems.
Seven-step western blot workflow diagram: sample lysis, protein quantification, SDS-PAGE, membrane transfer, blocking, antibody incubation and washing, and ECL or DAB signal detection, each labeled with BIORI product numbers
Figure 1. Seven-step western blot protocol with the corresponding BIORI product numbers for each stage.

Step 1: Sample Lysis

Sample lysis releases soluble proteins from cells or tissue; the key choices are lysis strength and inhibitor protection. RIPA Lysis Buffer (BR4C101–BR4C104) is intended for Western blot sample preparation from animal cells and tissues. Strong, medium and weak formulations support different target locations and sample types (Table 1).

Table 1. Lysis strength of RIPA lysis buffers and applicable proteins
Product Lysis strength Intended applications
RIPA Lysis Buffer (Strong), BR4C101 Strong Membrane, cytoplasmic and nuclear proteins
RIPA Lysis Buffer (Medium), BR4C102 Medium Routine cytoplasmic proteins
RIPA Lysis Buffer (Weak), BR4C103 Weak Cytoplasmic proteins, gentler lysis, protein complexes

Cell lysis also releases proteases and phosphatases. Add a protease inhibitor to every lysate and include phosphatase inhibition when analyzing phosphorylated targets. The Protease and Phosphatase Inhibitor Cocktail, EDTA-Free (100×) (BR4C123) combines both inhibitor classes in one concentrate. Dilute to 1× and add it immediately before lysis. Faint bands with small degradation fragments can indicate proteolysis; a weak phospho-signal with normal total protein can indicate inadequate phosphatase inhibition.

Table 2. Selection of protease and phosphatase inhibitors
Inhibitor Main components Coverage Application scenarios
Protease Inhibitor Cocktail, EDTA-Free (100×), BR4C121 AEBSF, aprotinin, bestatin, E-64, leupeptin, pepstatin A Serine, cysteine and aspartic proteases; aminopeptidases Total protein, non-phosphorylated targets
Phosphatase Inhibitor Cocktail (100×), BR4C122 Sodium fluoride, β-glycerophosphate (sodium salt), sodium orthovanadate Acid, serine/threonine, alkaline and tyrosine phosphatases Used with the protease cocktail for phosphorylated blots
Protease and Phosphatase Inhibitor Cocktail, EDTA-Free (100×), BR4C123 The two sets above combined in one stock solution Proteases and phosphatases Phosphorylated Western blot completed with a single addition

Tip: never pre-mix inhibitors into lysis buffer for storage — add them fresh, just before the lysis starts.

Step 2: Protein Quantification

Protein quantification normalizes total protein across lanes so band intensities can be compared. The BCA method (BCA Protein Assay Kit, BR4C201) generally tolerates detergents better; the Bradford method (Bradford Protein Assay Kit, BR4C202) is fast and compatible with many reducing agents.[2,3] Because RIPA lysates contain detergents, check the assay compatibility table before testing, dilute or precipitate the sample when appropriate, or select a validated detergent-tolerant workflow.[4]

Tip: check assay compatibility before choosing — reducing agents, detergents and chelators are the usual culprits.

Step 3: SDS-PAGE Electrophoresis

SDS-PAGE separates denatured proteins by molecular weight.[5] Select a gel percentage that places the target near the middle of the resolving range.[8] Use 5× SDS-PAGE Protein Loading Buffer (BR4C351) for sample preparation and 10× Tris-Glycine-SDS Running Buffer (BR4C361) for Tris-Glycine electrophoresis.

Higher-percentage gels resolve smaller proteins, whereas lower-percentage gels resolve larger proteins (Figure 2). The One-Step PAGE Gel Fast Preparation Kit series (BR4C331–BR4C335) covers 6% to 15% gels. Load the 180 kDa Prestained Protein Marker (BR4C303) in one lane to monitor electrophoresis and later assess transfer (Figure 3).

Prestained marker patterns on 6%, 7.5%, 10%, 12.5% and 15% One-Step PAGE gels showing the molecular-weight range each gel percentage resolves
Figure 2. Molecular-weight ranges resolved by 6%, 7.5%, 10%, 12.5% and 15% One-Step PAGE gels (BR4C331–BR4C335; BIORI internal data).
180 kDa prestained protein marker on a 15% SDS-PAGE gel after electrophoresis and after transfer to 0.22 µm PVDF and NC membranes
Figure 3. Prestained protein marker (BR4C303) after electrophoresis and after transfer (BIORI internal data. Transfer conditions: proteins separated on a 15% SDS-PAGE gel were transferred at a constant current of 500 mA for 20 min onto PVDF Membrane, 0.22 μm (BR4D412) and NC Membrane, 0.22 μm (BR4D414), respectively.)

Tip: a common starting point is 20–30 µg of total protein per lane for cell lysates, and always include a marker lane.[1]

Step 4: Membrane Transfer

Transfer moves separated proteins from the gel to a membrane for antibody detection.[6] Conventional wet transfer with Tris-Glycine-methanol buffer commonly takes about 45 min to 2 h, depending on protein size and equipment.[6,8] 10× Fast Transfer Buffer (BR4D421) is a separate rapid wet-transfer workflow specified for 20–40 min, with an ice pack inside the tank and no external ice bath.

PVDF membrane (>200 µg/cm²; BR4D411) requires methanol activation and tolerates stripping and reprobing, whereas NC membrane (>115 µg/cm²; BR4D413) is wetted with water (BIORI product data). For small proteins below 20 kDa, select a 0.22 µm membrane; for proteins above 20 kDa, 0.45 µm is the usual starting point (Table 3). Judge transfer on both sides: the gel should retain no obvious target or marker bands, and the membrane should show intact, undistorted bands without bubble-shaped gaps (Figure 4).

Table 3. Comparison of BIORI NC and PVDF membrane options
Item NC membrane PVDF membrane
Pore size options 0.22 µm, 0.45 µm 0.22 µm, 0.45 µm
Protein binding capacity >115 µg/cm² >200 µg/cm²
Methanol pre-wetting No — wet with water Yes
Fluorescence background Very low Higher
Stripping and reprobing Not recommended Recommended
Detection methods Chemiluminescence, fluorescence or colorimetric detection Chemiluminescence or colorimetric detection
Pore-size guidance NC: 0.22 µm (BR4D414) for proteins <20 kDa; 0.45 µm (BR4D413) for proteins >20 kDa. PVDF: 0.22 µm (BR4D412) for proteins <20 kDa; 0.45 µm (BR4D411) for proteins >20 kDa.
Ideal western blot transfer result: gel with no residual marker bands and a PVDF membrane with intact, undistorted prestained marker bands
Figure 4. Ideal transfer result using a 10% SDS-PAGE gel, 0.45 µm PVDF membrane (BR4D411), 3–7 µL BR4C303 marker, 500 mA for 20 min and 10× Fast Transfer Buffer (BR4D421; BIORI internal data).

Tip: if the marker pattern stays in the gel, extend the transfer time before blaming the antibody.

Step 5: Blocking

Blocking occupies unbound membrane sites and reduces nonspecific antibody binding.[7] Use 5% skim milk for routine non-phosphorylated targets or 3–5% BSA when milk casein may interfere. 5× Rapid Blocking Buffer (BR4D441) is a protein-free option that works in 5–15 min and is designed not to mask epitopes. Because blocker performance depends on the antibody–antigen pair, compare conditions side by side when background or signal remains suboptimal.

Tip: for phosphorylation targets, avoid skim milk — its casein is itself a phosphoprotein and raises the background.

Step 6: Antibody Incubation and Washing

Antibody incubation binds the primary antibody to the target and an HRP-labeled secondary antibody to the primary; washing controls the signal-to-noise ratio. A common starting workflow is primary antibody at 4 °C overnight, three 5–10 min washes with 10× TBST Buffer (BR4D451) diluted to 1×, secondary antibody for 1 h, and another three washes (Table 4). Prepare the western blot buffers fresh: 10× running buffer (BR4C361), 10× transfer buffer (BR4D421), 5× blocking buffer (BR4D441) and 10× TBST (BR4D451).

Table 4. Routine antibody-incubation and washing conditions
Step Routine conditions Principle and function
Primary antibody incubation 4 °C overnight, or 1–2 h at room temperature The primary antibody binds the antigenic epitope of the target protein
Washing TBST 3 × 5–10 min Removes unbound and weakly adsorbed antibody, retaining high-affinity specific binding
Secondary antibody incubation 1 h at room temperature, typically ≥1:2000 dilution The HRP-labeled secondary binds the primary constant region, amplifying the signal
Final washing TBST 3 × 5–10 min Removes free secondary antibody so its HRP cannot catalyze the substrate into background

Tip: do not shorten the final wash — residual free secondary antibody is the most common cause of uniform high background.

Step 7: Signal Detection

HRP-based chemiluminescence provides sensitive imaging, whereas DAB provides a visible brown precipitate without a chemiluminescence imager. In chemiluminescent detection with ECL Chemiluminescent Substrate Kit (BR4D602), HRP oxidizes luminol and the emitted light is captured by a CCD imager or X-ray film. DAB Peroxidase Substrate Kit (BR4D601) suits direct visual documentation (Figure 5). If multiple targets must be detected on one membrane, strip and re-incubate the blot; PVDF generally tolerates stripping better than NC (Table 3).

Diagram of DAB and ECL detection principles with HRP-labeled antibodies, next to DAB and ECL blots of a serially diluted His-tagged protein
Figure 5. DAB and ECL principles and serial-dilution results (BR4D601–BR4D602; BIORI internal data).

Tip: image ECL blots soon after adding substrate — the signal decays over time, and weak bands benefit from longer exposure.

FAQ

How should I store a western blot membrane after transfer or detection?

After transfer, keep the membrane wet in TBST at 4 °C if the next incubation will occur within 1–2 days. For a longer pause, a PVDF membrane may be air-dried after transfer and reactivated with methanol before use; confirm the procedure for the specific membrane and target. After detection, archive the original image and keep the membrane wet at 4 °C if stripping or reprobing is planned. Avoid repeated freeze–thaw cycles.

What controls should I include in a western blot?

Four at minimum: a positive control (a sample known to express the target), a negative control (one that does not), a loading control (β-actin, GAPDH or tubulin) for normalization, and a prestained protein marker for molecular weight and transfer efficiency. A lane without primary antibody can be added to check nonspecific secondary-antibody binding.

How long does a western blot take?

A full western blot usually takes about 1–2 days. Sample lysis, quantification, gel electrophoresis, transfer, blocking and washing each take tens of minutes to a couple of hours, and the overnight primary-antibody incubation at 4 °C accounts for most of the waiting time — with incubation set up on day one, secondary-antibody incubation and signal detection are finished on day two.

Can I use an HRP-labeled primary antibody without a secondary antibody?

Yes. Direct labeling shortens the workflow and avoids secondary-antibody cross-reactivity, but indirect detection amplifies the signal because several secondary antibodies bind one primary, so sensitivity is usually higher. Directly labeled primaries cost more and may lose activity during labeling — use them when speed or a clean single-species background matters.

These parameters are general starting points for chemiluminescent Western blotting with standard Tris-Glycine gels. Fluorescent detection, proteins above 300 kDa and proteins below 10 kDa usually require adjusted transfer and blocking conditions.[1,8] BIORI products are for research use only and are not intended for diagnostic procedures. Explore the full life-science portfolio in the BIORI protein research catalog. For product selection guidance, see the life science research selection page.

References

  1. Mahmood T, Yang PC. Western blot: technique, theory, and trouble shooting. N Am J Med Sci. 2012;4(9):429–434. https://pmc.ncbi.nlm.nih.gov/articles/PMC3456489/
  2. Bradford MM. A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. Anal Biochem. 1976;72:248–254. https://doi.org/10.1016/0003-2697(76)90527-3
  3. Smith PK, Krohn RI, Hermanson GT, et al. Measurement of protein using bicinchoninic acid. Anal Biochem. 1985;150:76–85. https://doi.org/10.1016/0003-2697(85)90427-0
  4. Thermo Fisher Scientific. Protein quantitation assay compatibility table (Tech Tip TR0068). https://assets.thermofisher.com/TFS-Assets/LSG/Application-Notes/TR0068-Protein-assay-compatibility.pdf
  5. Laemmli UK. Cleavage of structural proteins during the assembly of the head of bacteriophage T4. Nature. 1970;227:680–685. https://doi.org/10.1038/227680a0
  6. Towbin H, Staehelin T, Gordon J. Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications. Proc Natl Acad Sci USA. 1979;76:4350–4354. https://doi.org/10.1073/pnas.76.9.4350
  7. Kurien BT, Scofield RH. Western blotting. Methods. 2006;38:283–293. https://doi.org/10.1016/j.ymeth.2005.11.007
  8. Thermo Fisher Scientific. Overview of western blotting (Pierce protein methods library). https://www.thermofisher.com/us/en/home/life-science/protein-biology/protein-biology-learning-center/protein-biology-resource-library/pierce-protein-methods/overview-western-blotting.html
Share
Biori

Zhuhai Biori Biotechnology Co., Ltd. provides biological raw materials and reagent solutions for life science research, in vitro diagnostics (IVD), and biopharmaceutical applications.

Put it into practice

Need help choosing a reagent or format?

Tell us about your application, sample type and reagent requirements. Our team replies within one business day.

Talk to an expert

Not ready for a quote? Discuss feasibility, formats, host systems or validation with an application scientist.

Topic: your enquiry

Reply within one business day from an application scientist. For pricing, COA or samples, use Request a quote instead.

Application scientistAssay integration & formats

Tell us what you want to discuss

A short form. We route it to the right person and reply the way you prefer.

🔒 Used only to reply to this request. No newsletters. Privacy Policy

Need pricing, a COA or samples? Request a quote →

Quick Contact

Used only to reply to this enquiry. Privacy Policy